Supported devices
Barrier - Alphatronics SmartOne
Supported platforms
smartcontroller imx7
Supported hardware
1-010104-xxxx-xxx-xxx-xx
Supported data contracts
Inputs : 5 digital inputs (value 0 or 1)
in_continuous_close : indicates if the continuous close hardware input is shorted.
in_continuous_open : indicates if the continuous open hardware input is shorted.
in_pulse_open : indicates if the pulse open hardware input is shorted.
in_pulse_close : indicates if the pulse close hardware input is shorted.
in_security_1 / in_security_2 : indicates if the security inputs are shorted.
Smartcard reader - China Creator CRT-288
Supported platforms
smartcontroller imx7
smartcontroller imx6
gateway
Supported hardware
4-080504-0009-000
hardware interfaces: USB2.0
Supported data contracts
-
smartcards: BEID
Barcode scanner, Newland FM3056
Supported platforms
smartcontroller imx7
smartcontroller imx6
gateway
Supported hardware
4-080503-0013-000
Supported data contracts
Barcode scanner, Newland FM3281
Supported platforms
gateway
Supported hardware
4-080503-0013-000
Supported data contracts
Input Output Module - Alphatronics AP3010
Supported platforms
smartcontroller imx7
smartcontroller imx6
Supported hardware
3-020301-3010-200
Supported data contracts
Webcam - UVC (custom project)
Supported platforms
smartcontroller imx7
smartcontroller imx6
gateway
Supported hardware
Any uvc webcam, but tested with Qipan QP-2099V1.0 webcam
Supported data contracts
Input Output module - Alphatronics AP286
Supported platforms
smartcontroller imx7
gateway
Supported hardware
3-020301-0286-000
hardware interfaces: rs485 (TODO: productnumbers interfaces…)
See Alphatronics AP298, AP338, AP286 configuration to learn more about the advised configuration setup for this device in combination with the HALAPI.
Supported data contracts
-
OUTD1 … OUTD4 : 4 relays (value 0 or 1)
-
IND1 … IND4 : 4 general purpose digital inputs or (directional aware or non-aware) triggers for passage counters (value 0 or 1)
-
MEM1 … MEM4 : 4 passage counters (directional aware or non-aware). Max value depends on memory type (will be reset to 0 in case of overflow). All memory types and data sizes are supported.
Tip
Memory and/or Input event support is dependent on the loaded script.
Possible output parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
Persistent set to value 0 |
Toggle |
x |
x |
x |
x |
Not supported |
Set |
[0,1] |
0 |
0 |
0 |
Set persistently to Value1 |
Set |
[0,1] |
>100 |
0 |
0 |
Set to Value1 for x ms, then persistent set to value 0 (Set Pulse) |
Interval |
[0,1] |
>100 |
[0,1] |
>100 |
Set to Value1 for x ms, then set to Value2 for x ms and repeat this endlessly. |
RFID and Barcode scanner - STid ((custom project)
Supported platforms
smartcontroller imx7
gateway
Supported hardware
4-080511-0001-000 (barcodeScanner / rfidscanner / indicators)
4-080502-0024-000 (rfidscanner / indicator)
See RFID and Barcode scanner, STid configuration to learn more about the advised configuration setup for this device in combination with the HALAPI.
Supported data contracts
-
LED1 : RGB3 led
BUZZER1 : buzzer
Possible buzzer parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
BUZZER1 off |
Toggle |
x |
x |
x |
x |
Not supported |
Set |
>0 |
0 |
0 |
0 |
Not supported |
Set |
>0 |
1000 |
0 |
0 |
Value1 = always 1, Time1: 0…60000, BUZZER1 on for x ms |
Set |
0 |
0 |
>=0 |
>0 |
Not supported |
Interval |
>=0 |
1000 |
>=0 |
1000 |
Value1/Value2 = [0,1], Time1/Time2: 0…60000, BUZZER1 on and off indefinitely |
Possible LED parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
LED1 off |
Toggle |
x |
x |
x |
x |
Not supported |
Set |
>0 |
0 |
0 |
0 |
Not supported |
Set |
>0 |
1000 |
0 |
0 |
Value1 = RGB3 value , Time1: 0…25600, LED1 on for x ms |
Set |
0 |
0 |
>=0 |
>0 |
Not supported |
Interval |
>=0 |
1000 |
>=0 |
1000 |
Value1/Value2 = RGB3 value; Time1/Time2: 0 … 25600, LED1 on and off indefinitely |
The supported RGB3 values for value1 and value2 are
Color |
RGB3Value |
Black |
0x000000 |
Red |
0xFF0000 |
Green |
0x00FF00 |
Blue |
0x0000FF |
Amber |
0xFFBF00 |
Magenta |
0xFF00FF |
Cyan |
0x00FFFF |
White |
0xFFFFFF |
The supported time values are <=100 ms
Example request:
POST /hal/devices/stid1/indicators HTTP/1.1 Accept: application/json Authorization: Bearer eyJhbGciOiJS... [ { "name": "LED1", "state" : 1, "value1" : 0x000FF, "time1" : 1000, "value2" : 0, "time2" : 0, "type" : 2 }, { "name": "BUZZER1", "state" : 1, "value1" : 1, "time1" : 1000, "value2" : 0 "time2" : 0, "type" : 1 } ]
RFID- and Keycode scanner - Alphatronics AP298
Supported platforms
smartcontroller imx7
gateway
Supported hardware
3-020301-0298-000
See Alphatronics AP298, AP338, AP286 configuration to learn more about the advised configuration setup for this device in combination with the HALAPI.
Supported data contracts
Outputs : for possible output parameter values, see AP286 device
OUTD1 : 1 relay (value 0 or 1)
-
IND1 : 1 general purpose digital input
-
LED1 : RGB24 led
LED2 : RGB24 led
BUZZER1 : buzzer
Possible LED parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
indicator off |
Toggle |
x |
x |
x |
x |
Not supported |
Set |
>0 |
0 |
0 |
0 |
Value1 = RGB24 value |
Set |
>0 |
>0 |
0 |
0 |
Value1 = RGB24 value, Time1: >0 (in ms) |
Set |
0 |
0 |
>0 |
>0 |
Not supported |
Interval |
>0 |
>0 |
>=0 |
>0 |
Value1/Value2 = RGB24 value, Time1/Time2: >0 (in ms), on and off indefinitely |
Possible buzzer parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
indicator off |
Toggle |
x |
x |
x |
x |
Not supported |
Set |
[0,1] |
0 |
0 |
0 |
Value1 = 0/1 |
Set |
[0,1] |
>0 |
0 |
0 |
Value1 = 0/1, Time1: >0 (in ms) |
Interval |
[0,1] |
>0 |
[0,1] |
>0 |
Value1/Value2 = 0/1, Time1/Time2: >0 (in ms), on and off indefinitely |
RFID scanner - Alphatronics AP338
Supported platforms
smartcontroller imx7
gateway
Supported hardware
3-020301-0298-000
See Alphatronics AP298, AP338, AP286 configuration to learn more about the advised configuration setup for this device in combination with the HALAPI.
Supported data contracts
Outputs : for possible output parameter values, see AP286 device
OUTD1 : 1 relay (value 0 or 1)
-
IND1 … IND3 : 3 general purpose digital inputs (input1 can be used to connect a pushbutton)
-
LED1 : RGB3 led
BUZZER1 : buzzer
Possible LED parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
indicator off |
Toggle |
x |
x |
x |
x |
Not supported |
Set |
>0 |
0 |
0 |
0 |
Value1 = RGB3 value |
Set |
>0 |
>0 |
0 |
0 |
Value1 = RGB3 value, Time1: >0 (in ms) |
Set |
0 |
0 |
>0 |
>0 |
Not supported |
Interval |
>0 |
>0 |
>=0 |
>0 |
Value1/Value2 = RGB3 value, Time1/Time2: >0 (in ms), on and off indefinitely |
Possible buzzer parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
indicator off |
Toggle |
x |
x |
x |
x |
Not supported |
Set |
[0,1] |
0 |
0 |
0 |
Value1 = 0/1 |
Set |
[0,1] |
>0 |
0 |
0 |
Value1 = 0/1, Time1: >0 (in ms) |
Interval |
[0,1] |
>0 |
[0,1] |
>0 |
Value1/Value2 = 0/1, Time1/Time2: >0 (in ms), on and off indefinitely |
Barrier - Alphatronics DBK
Supported platforms
smartcontroller imx7
gateway
Supported hardware
1-010105-000x-xxx-xxx-00 combined with IP module 4-080101-0093-000
See Barrier, Alphatronics DBK configuration to learn more about the advised configuration setup for this device in combination with the HALAPI.
Supported data contracts
Inputs :
IND1 … IND3 : respectively linked to induction loops a, b & c.
Outputs :
OUTD1 … OUTD6 : respectively linked to multi-functional relays 1 … 6. Note that the ‘pulse time’ of a pulse command is fixed as it is pre-configured by the dbk.
Possible output parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
Persistent set to value 0 |
Toggle |
x |
x |
x |
x |
Not supported |
Set |
[0,1] |
0 |
0 |
0 |
Set persistently to Value1 |
Set |
1 |
100 |
0 |
0 |
Pulse for a fixed time (Time1 is ignored, but must be >= 100) |
Interval |
x |
x |
x |
x |
Not supported |
Input Output module - WuT Web IO 57738
Supported platforms
smartcontroller imx7
gateway
Supported hardware
4-080404-0008-000
See Input Output module, WuT Web IO 57738 configuration to learn more about the advised configuration setup for this device in combination with the HALAPI.
Supported data contracts
Inputs :
IND1 … IND12 : respectively linked to IN0…IN11
Outputs :
OUTD1 … OUTD8 : respectively linked OUT0…OUT7
-
MEM1 … MEM12 : respectively linked to IN0…IN11. It is possible to configure the counters for bi-directional counting (eg count only if IN1 is triggered and released after IN0 is triggered and released within x time))
Possible output parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
Persistent set to value 0 |
Toggle |
x |
x |
x |
x |
Not supported |
Set |
[0,1] |
0 |
0 |
0 |
Set persistently to Value1 |
Set |
1 |
100 |
0 |
0 |
Pulse for a fixed time (Time1 is ignored, but must be >= 100) |
Interval |
x |
x |
x |
x |
Not supported |
ANPR - Avutec module-X IR (custom project)
Supported platforms
gateway
Supported hardware
4-070101-0009-100
See ANPR, Avutec module-X IR configuration to learn more about the advised configuration setup for this device in combination with the HALAPI.
Supported data contracts
Counter display - RGB Technology
Supported platforms
gateway
Supported hardware
3-040701-0001-100
3-040701-0002-100
See RGBTechnology configuration to learn more about the advised configuration setup for this device in combination with the HALAPI.
Supported data contracts
-
name: COUNTER1 … COUNTER6 respectively linked to RGBTechnology memorycells 1 … 6 for color1 and 7 … 12 for color2.
value:
Range: [0…999], text on display is always outlined to 3 digits
If value is ‘null’, the text ‘—’ will be displayed.
color: depends on the color assigned to the related memorycells.
Electronic Payment - Payter Apollo
Supported platforms
gateway
Supported hardware
4-080807-0038-000
See RGBTechnology configuration to learn more about the advised configuration setup for this device in combination with the HALAPI.
Supported data contracts
Input Output module - Alphatronics Gateway
Supported platforms
gateway
Supported hardware
1-040199-0007-000-000-00
1-040199-0009-000-000-00
1-040199-0012-000-000-00
1-040199-0013-000-000-00
Supported data contracts
Inputs :
IND1 … IND4 : respectively linked to IN0…IN4
Outputs :
OUTD1 … OUTD4 : respectively linked OUT0…OUT3
Possible output parameter values:
State |
Value1 |
Time1 |
Value2 |
Time2 |
Result |
Reset |
x |
x |
x |
x |
Persistent set to value 0 |
Toggle |
x |
x |
x |
x |
Toggles between 1 and 0 |
Set |
[0,1] |
0 |
0 |
0 |
Set persistently to Value1 |
Set |
1 |
100 |
0 |
0 |
Pulse for Time1 [100,300000] |
Interval |
x |
x |
x |
x |
Not supported |
Wastebin - OAIII (custom project)
Supported platforms
gateway
Supported hardware
not specified
Supported data contracts
none
Supported direct methods
Pair : starts the pairing (bonding) process for an OAIII devices.
CommandId : 1
Data:
{ }
ConfirmPasskey : allows passing the passkey displayed on the OAIII container to approve and finalize the pairing process.
CommandId : 2
Data:
{ "passkey": 123456 // integer value of exact 6 digits }
Unpair : starts the BLE unpairing process
CommandId : 3
Data:
{ }
Supported direct queries
State : retrieves the detailed status of the OAIII bin.
QueryId : 1
Response:
{ "binStatus": 1, //OAIIIBinState "isTrusted": true, "isPaired": true, "isBonded": true }
SessionState : retrieves the dumping session status of the OAIII bin.
QueryId : 2
Response:
//if session found: { "state": 1, //WasteDumpState "id": 1, //session id "startedUtc": "2025-09-18T10:24:05.1031086+02:00" //session creation time (utc) } //if no session found: status code 404: Not found
OAIIIBinState
Unknown = 0,
Ready = 1,
Binfull = 2,
Binopen = 3,
Blockage = 4,
Unlocked = 5
WasteDumpState
Unknown = 0
Success = 1
Dumping = 2
Failed = 3
Notfound = 4
Cash Payment - WHBerlin Coin Acceptor (custom project)
Supported platforms
gateway
Supported hardware
EMP 890.14v7
Supported data contracts
Display - Alphatronics Gateway
Supported platforms
gateway
Supported hardware
1-040199-0008-000-000-00
1-040199-0009-000-000-00
1-040199-0011-000-000-00
1-040199-0013-000-000-00
Supported data contracts