.. _SystemIntegration_GeneralParkingAndZones: ########################## Parkings & Zones - General ########################## .. _SystemIntegration_ZoneCounting_ParkingAndZones: Parkings and parking zones ************************** A parkings can contain one or more parking zones. Parkings and parking zones have different features. Parkings: * Occupancy (count and state) is based on the its parkings zones. - A 'threshold free' parameter can be set (through ALIOT), to prevent the parking state from 'jittering' (continu free <=> full state changes). - A 'daily reset' parameter can be set (through ALIOT), to reset the current occupancy count. * Outputs can be set automatically based on the the occupancy state. This way a parking can be closed or a free/full display can be set * Counter actions can be sent automatically based on the occupancies. This way a display can be updated. Zones: * Counting is done on parking zone level by counting loops placed in the ground. * The occupancy state is calculated on parking zones level. See :ref:`Occupancy state ` for more info. * Outputs can be set automatically based on the the occupancy state. This way a zone can be closed or a free/full display can be set. * Counter actions can be sent automatically based on the occupancies. This way a display can be updated. .. _SystemIntegration_ZoneCounting_Parking_Logs: Parking logs ************ Parkings logs are created in case of: * A passage, when the maximum number of passages before writing a log is reached (see parameters below) * A timer, when the maximum timespan before writing a log has passed (see parameters below) * A daily reset event happening * An API call modifying the occupancy of a zone: /increase-occupancy, /decrease-occupancy, /update-occupancy and /reset-occupancy * An API call modifying the occupancy of a parking: /reset-occupancy * An API call modifying the state of a zone: /update-state * An API call modifying the state of a parking: /update-state * Upon modifying settings in ALIOT, if this leads to the maximum amount of passages before writing a log being reached * Upon startup The following parameters (set through ALIOT) have impact on the frequency of log creation: * Max time between 2 logs * Max amount of passages before log creation Each log contains the following properties: * Id: unique log id * ParkingName: name of the parking as defined in ALIOT. * TimeCreated: utc creation time of the logs * OccupancyState: the state of the parking at the time of the log being created. See :ref:`occupancy state ` for more info. * Occupance: number of occupied parking spaces at the time of the log being created * ThresholdFree: number of free places before the OccupancyState goes from Full/OutofService to Free * Capacity: total amount of parking spaces .. _SystemIntegration_ZoneCounting_Parking_OccupancyStateIds: Enumeration occupancy states **************************** - Free = 0 - Full = 1 - OutOfService = 2